Mitsubishi Electronics 13JW55 ユーザーズマニュアル
App. - 21
Appendix 4.14 Switching timer set value externally
(1) With an external switch, a value to be set in one timer can be selected from
three patterns; 1sec., 10sec., and 100sec.
A timer is activated and reset with a push button switch.
X0
1sec.
X1
10sec.
X2
100sec.
X3
Starts timer
X4
Resets timer
PB
PB
SC
Input power supply
Load power supply
Y70
Y70
Y70
MC
RL
OL
Load
Indicates the timer
has gone time out.
has gone time out.
Indicates the timer
is in operation.
is in operation.
Project name
QA-22
Program name
MAIN
Y70
X0
M0
0
12
Set value 1sec.
Starts timer
Turns on while timer
is in operation
is in operation
X1
3
D0
K100
MOV
D0
K10
MOV
X2
6
X3
9
D0
K1000
MOV
M0
SET
X4
11
M0
RST
T8
D0
Y72
T8
19
Y71
Stops timer
Set value 10sec.
Set value 100sec.
Turns on by time-out