Motorola SG 2000 ユーザーズマニュアル

ページ / 105
   
O p e r a t i o n  
5 - 1 5  
 
SG  20 00  Ins tal la tion  and  O pera tion  M anua l 
Feature Desc ription 
Transmitter enable 
A green LED that provides visual indication of the transmitter’s 
enable status. 
Fault indicator 
A single red LED that lights when the hybrid current is outside the 
normal operating range, the laser output power is below normal 
limits, or the laser current is above normal limits. Because the laser 
output requires a short period of time to stabilize, it is acceptable 
for the fault indicator to illuminate during the stabilization interval 
(approximately 2 seconds). Note that the module must be enabled 
for the fault indicator to function. 
SG2-FP T Op tica l Transmitte r 
The SG2-FPT is a non-isolated Fabry-Perot return-path optical transmitter designed for use in the SG 
2000 node platform. It has a nominal optical output power of 0.4 mW and can be used in conjunction 
with an AM-RPR, AM-OMNI-RPR/2, or other similar return path optical receiver. Figure 5-17 
illustrates the SG2-FPT: 
F i g u r e   5 - 1 7   
S G 2 - F PT  
F
A
U
L
T
O
N
LASER
CURRENT
(1 V/A)
OPTICAL
POWER
(1 V/mW)
SG2000
Optical Transmitter
ASSEM BLED
IN  MEXICO
SG2-FPT
 
Table 5-4 provides information on the user-related features of the SG2-FPT: 
T a b l e   5 - 4    
SG 2 - F PT   f e a t u r e s  
Feature Desc ription 
Optical power test point 
This test point enables monitoring of the optical output level of the 
module. The nominal scale factor is 1.0 V/mW. The optical power 
test point voltage is between 0.375 V and 0.425 V (optical power of 
0.375 mW through 0.425 mW) when the module is enabled under 
normal operating conditions. Note that the optical power test point 
does not track changes in optical power due to the laser tracking 
error. 
Laser current test point 
This test point enables monitoring of the current drawn by the laser 
diode. The nominal scale factor is 1.0 V/A. The laser current test 
point voltage is between 4 mV through 90 mV (laser current of 
4 mA through 90 mA) when the module is enabled under normal 
operating conditions. The laser current is expected to vary widely 
with changes in temperature, but should always remain between 
the limits.