6-10 Troubleshooting Guide
T
roubleshooting
326X Series Modem Diagnostic Tests
The modem supports loopback, busy out, and retrain tests to assist you in isolating 
network problems. These tests analyze the telephone line and the local and remote 
modem’s performance. These tests can be initiated from the modem’s front panel, 
using AT commands from an attached PC or terminal, or from a network 
management system.
The following table shows the  AT commands to initiate and terminate tests. The 
steps following the table describe how to initiate and terminate each test from the 
front panel. (Refer to your network management system documentation for 
instructions on initiating and terminating tests from the network management 
system.)
IMPORTANTThe tests described in this section cannot be run simultaneously. 
Because each test interrupts data flow in a network, notify equipment users at both 
the local and remote sites before starting tests.
For details on tests, refer to Chapter 4 of the 326X Series Modem Reference Guide
Test Description
AT 
Command
Local Analog 
Loopback 
Tests the local modem’s transmit and receive circuits 
by looping local DTE data from the modem’s 
transmitter to its receiver.
&T1
Local Analog 
Loopback Pattern
Tests the local modem’s transmit and receive circuits 
with an internally generated test pattern.
&T8
Remote Digital 
Loopback 
Using local DTE data, this test examines the transmit 
and receive circuits of the local and remote modems 
and the telephone line.
&T6
Remote Digital 
Loopback Pattern
Tests the transmit and receive circuits of the local and 
remote modems and the telephone line.
&T7
Data Mode Pattern  The modem uses internally generated test patterns to 
provide data and separately test the inbound and 
outbound halves of the transmission path.
Not 
applicable
Local Digital 
Loopback 
Using the remote DTE data for the test, the telephone 
lines and the remote modem circuits are tested.
&T3
Busy Out
Allows the modem to appear busy to incoming calls.
H1
Retrain
Lets you manually retrain local and remote modems.
O1
(Terminate)
Terminates any test in progress.
&T0