Motorola 326X V.34 ユーザーズマニュアル

ページ / 240
5-4 Using the AT Automatic Calling Interface
Using the
A
T
 ACU
To enter multiple AT commands on a single command line:
Multiple AT commands can be entered on a command line using a single AT prefix. 
The modem accepts up to 60 characters after the prefix. Spaces are not counted in the 
length. AT commands are interpreted in sequence in the command line until one of 
the following occurs:
• A <CR> is encountered
• An invalid command is encountered
• A command is encountered which causes the modem to reset, go off-hook, or 
enter a test state
For example, you might enter:
ATE0V1&W<CR>
on a single command line. This command disables Asynchronous Echo. It configures 
the Result Code Format to Verbose, and the Save Changes feature to Option Set 1. 
(These options and settings are described fully in Appendix A.)
Commands that are followed by a telephone number must be at the end of the line. 
However, if the semicolon dial modifier (;) follows a telephone number, the modem 
returns to command mode after dialing. Therefore, AT commands can be entered 
after a semicolon in a command string. NOTE: If an error occurs, AT commands 
prior to the error are executed; commands following the error are ignored.
If you enter an AT command that requires a postscript number and no number is 
entered, the modem defaults to a 0 setting.
AT Command String Examples
Table 5-1 provides AT command string examples and their ACU results.
For Further Detail on AT Commands
For a description of AT commands, and dial modifiers, refer to Appendix A.
Table 5-1. 
Interpreting AT Command Strings
 
Command
Interpretation
AT&X<CR>
Postscript number needed and none is provided. 0 is assumed. 
Transmitter timing is set for internal.
ATS2
No response. Needs a carriage return after the command.
GATE0<CR>
Ignores everything before the AT prefix. The G is ignored. This 
command disables the asynchronous echo feature.
ATS2?Q=1<CR>
Multiple command line. Selects S-Register 2 as the current S-Register, 
displays contents of S-Register 2, turns on result code displays, and 
sets S-Register 2 to 1.