Motorola MPMC101 ユーザーズマニュアル
Installing the PMC SCSI-2 Adapter
2-11
2
!
Caution
Make sure the electrical configuration (single-ended or
differential) of the PMC Adapter matches the common
termination type of the device(s) that will be connected
to the SCSI bus. A mixed installation can cause electrical
damage to both the peripherals and to the PMC
Adapter.
differential) of the PMC Adapter matches the common
termination type of the device(s) that will be connected
to the SCSI bus. A mixed installation can cause electrical
damage to both the peripherals and to the PMC
Adapter.
!
Warning
Your computer operates with voltages that can be lethal.
Before you remove the computer cover, carefully review
the steps in this procedure and observe all cautions and
warnings to protect yourself and to prevent damage to
the system.
Before you remove the computer cover, carefully review
the steps in this procedure and observe all cautions and
warnings to protect yourself and to prevent damage to
the system.
1. With power disconnected and the motherboardÕs faceplate
screws unfastened, remove the motherboard from the system
chassis.
chassis.
2. Remove the spring metal clip covering the mezzanine
aperture on the face plate of the motherboard.
3. With a grounding strap attached to your wrist or ankle,
carefully remove the adapter from its antistatic bag.
4. Set the jumpers on the PMC Adapter as described in
.
Terminators -
The SCSI bus (cable) must be properly
terminated at each end of the bus. The first and last device on
the bus should be the only devices that are set to provide this
function.
the bus should be the only devices that are set to provide this
function.
Terminator Power -
The SCSI terminators require adequate
voltage to properly terminate the cable. All SCSI host
adapters on the bus should be set to supply terminator
power; and where possible, be located at the end of the bus
and serve as cable terminators.
adapters on the bus should be set to supply terminator
power; and where possible, be located at the end of the bus
and serve as cable terminators.