Chapter 6 – Troubleshooting 
Multi-Tech Systems, Inc. MT5634IND User Guide  (S000369A) 
22 
 
Data Is Being Lost 
• 
If you are using data compression and a high speed serial port, set the serial port baud rate to two to six 
times the data rate. 
• 
Make sure the flow control method you selected in software matches the method selected in the modem.  
• 
Try entering the I11 command in online mode or the &V command in command mode to display information 
about the last connection, making a screen print of the connection statistics, and checking for parameters 
that might be unacceptable. 
 
There Are Garbage Characters on the 
Monitor 
• 
Your computer and the remote computer might be set to different word lengths, stop bits, or parities. If you 
have connected at 8-N-1, try changing to 7-E-1, or vice-versa, using your communication software. 
• 
You might be experiencing line noise. Enable error correction, if it is disabled, or hang up and call again; you 
might get a better connection the second time. 
• 
At speeds above 2400 bps, the remote modem might not use the same transmission or error correction 
standards as your modem. Try connecting at a slower speed or disabling error correction. (With no error 
correction, however, line noise can cause garbage characters.) 
• 
Try entering the I11 command in online mode or the &V command in command mode to display information 
about the last connection, making a screen print of the connection statistics, and checking for parameters 
that might be unacceptable. 
 
The Modem Doesn’t Work with Caller ID 
• 
Caller ID information is transmitted between the first and second rings, so if autoanswer is turned off (S0=0
or if the modem is set to answer after only one ring (S0=1), the modem will not receive Caller ID information. 
Check your initialization string, and if necessary change it to set the modem to answer after the second ring 
(S0=2). 
• 
Make sure that you have Caller ID service from your telephone company. 
Fax and Data Software Can’t Run at the Same 
Time 
• 
Communication devices can be accessed by only one application at a time. In Windows 95 and higher, you 
can have data and fax communication applications open at the same time, but they cannot use the same 
modem at the same time.