Multi-Tech Systems MTS2SA-T ユーザーズマニュアル

ページ / 181
Chapter 10 
− Modem Mode AT Commands, S-Registers, and Result Codes 
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 
117
 
 
 
Command: 
+PSS 
Use Short Sequence 
Description: 
 
Causes a calling modem to force either a V.92 short or full startup sequence as 
defined by the +PQC command on the next and subsequent connections. 
Defined Values:   
+PSS0  
The modems decide whether or not to use the short startup 
procedures. The short startup procedures can only be used if enabled 
by the +PQC command. (Default.) 
  
+PSS1 
 
Reserved. 
 
 
+PSS2  
Forces the use of the full startup procedures on the next and 
subsequent connections independent of the setting of the +PQC 
command. 
Result Codes: 
 
OK 0 - 2 in V.92 Mode (+MS=V.92) 
  
ERROR 
Report Commands: 
+PSS? 
Reports Selected Values. 
 +PSS=? 
Reporting 
Supported 
Range of Parameter Values 
 
 
 
 
 
Command: 
–QCPC 
Force Full Startup Procedure on Next Connection 
Description: 
 
Causes the modem to use full startup procedures on the next connection attempt 
regardless of the setting of the +PQC command. After this attempt, the modem will 
select the startup procedure as defined by the +PQC command. If a shortened 
startup procedure is enabled by the +PQC command, then the quick connect profile 
will also be updated on the next connection attempt. 
Result Code: 
 
OK In V.92 Mode (+MS=V.92) 
  
ERROR 
 
 
Command: 
–QCPS 
Enable Quick Connect Profile Save 
Description: 
 
This command controls whether or not the modem will save the generated quick 
connect profile.  
Defined Values:   
-QCPS0  
Do not allow the quick connect profile to be saved. 
 
 
-QCPS1  
Allow the quick connect profile to be saved. (Default.) 
Result Codes: 
 
OK in V.92 Mode (+MS=V.92) and quick connect is enabled (+PSS = 0) 
  
ERROR 
 
Report Commands: 
-QCPS? 
Reports Selected Value(s). 
 
 
-QCPS=? 