Multi-Tech Systems MTS2SA-T ユーザーズマニュアル
Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
19
General Commands – Setup
Command Syntax
set login
Description
Prompts the Login for the command shell when enabled, and doesn't when
disabled.
disabled.
Default Value
Enable
Success
OK
Error
1. Too few arguments
"Usage: set login <enable/disable>
Type 'set login ?' for more information"
2. Invalid
2. Invalid
string
"error: set login <enable/disable>"
Command Syntax
set login auto-dialout-login <enable/disable>
Description
Enables/Disables authentication for Telnet auto-dialout.
Default Value
Disable
Success
OK
Error
1. Too few arguments
"Usage: set login auto-dialout-login <enable/disable>
Type 'set login auto-dialout-login ?' for more information"
2. Invalid string
"error: set login auto-dialout-login <enable/disable>"
2. Invalid string
"error: set login auto-dialout-login <enable/disable>"
Command Syntax
set time <HH:MM:SS>
Description
Sets the system time.
Default Value
00:00:00
Success
OK
Error
1. Too few arguments
Usage: set date HH:MM:SS
Type 'set date ?' for more information
Error: Time in HH:MM:SS format
Too few arguments. Possible argument(s) are
ip login
serial date
ppp time
serial date
ppp time
Command Syntax
set watchdog <enable/disable>
Description
Enables/Disables the watchdog timer.
The timer value is set to 6.5 seconds. This is the upper threshold value.
The timer value is set to 6.5 seconds. This is the upper threshold value.
Note:
Watchdog timer comes into effect only after reboot. Hence,
invoking this command calls for a reboot on save.
Default Value
Enable
Success
OK
Error
1. Too few arguments
"Usage: set watchdog <enable/disable>
Type 'set watchdog <enable/disable> ?' for more information"
2. Invalid string
"error: set watchdog <enable/disable>"
2. Invalid string
"error: set watchdog <enable/disable>"