Multi-Tech Systems MTS2SA-T ユーザーズマニュアル

ページ / 181
Chapter 10 
− Modem Mode AT Commands, S-Registers, and Result Codes 
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 
95
 
 
Command: 
&V1 
Display Last Connection Statistics
 (&V1 has no functionality in V.22bis) 
Values:   n 
= 1 
Default:   1 
Description: 
 
Displays the last connections in the following format (shown with typical results): 
TERMINATION REASON.......... LOCAL REQUEST 
LAST TX rate................ 26400 BPS 
HIGHEST TX rate............. 26400 BPS 
LAST RX rate................ 49333 BPS 
HIGHEST RX rate………… 49333 
BPS PROTOCOL………….. LAPM 
PROTOCOL………………… LAPM 
COMPRESSION................. V42Bis 
Line QUALITY................ 038 
Rx LEVEL.................... 015 
Highest Rx State............ 67 
Highest TX State............ 67 
EQM Sum..................... 00B4 
Min Distance................ 0000 
RBS Pattern................. 00 
Rate Drop................... 00 
Digital Loss................ 2000 
Local Rtrn Count............ 00 
Remote Rtrn Count........... 00 
Flex 9481814347C4 
RBS Pattern
: Shows which bits are being robbed in the least significant 6 bytes, e.g., 03 
indicates 2 robbed bits in bit positions 0 and 1. 
Digital Loss
: Shows if a pad is encountered and if so, what is the digital loss. 2000 means 0dB. 
Flex
: Shows V.8bis information as follows: 
First byte
: Octet 13 (second byte of manufacturer id, 94 = K56flex) 
Second byte
: Octet 14 (Licensee code: 81 = Conexant) 
Third byte
: Octet 15 (manufacturer's product capabilities) 
  
Fourth byte
: Octet 16 (K56flex version number) 
  
Fifth byte
: Octet 17 (Conexant pump code version number) 
  
Sixth byte
: Octet 18 (x-law and controller version number) 
   
Bit 6  Forced/Not forced A-Law/
µ-Law 
   
0 =  Forced A-Law/
µ-Law 
   
1 =  Not forced A-Law/
µ-Law 
  
Bit 5 Select A-Law or 
µ-Law 
   
0 =  Select A-Law 
  
1 =  Select 
µ-Law 
   
Bit 4:0  Controller version 
 
Command: &Wn 
Store Current Configuration Settings 
(Not available in V.22bis) 
Values:   n 
= 0, 1
 
 
Default:   0 
Description: 
 
Saves the current (active) configuration (profile), including S-Parameters, in one of the two 
user profiles in NVRAM as denoted by the parameter value. The current configuration is 
comprised of a list of storable parameters illustrated in the &V command. These settings are 
restored to the active configuration upon receiving a Z command or at power up (see &Y 
command). 
 
 
&W0  Store the current configuration as profile 0. 
&W1  Store the current configuration as profile 1. 
 
Command: 
  &Y 
Designate a Default Reset Profile 
(No available in V.22bis) 
Values:   0, 
Default:   None 
Description: 
 
This command selects which user profile will be used after a hard reset. 
 
 
&Y0  The modem will use profile 0. 
&Y1  The modem will use profile 1.