Chapter 10 
− Modem Mode AT Commands, S-Registers, and Result Codes 
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 
98
 
 
Command:  
Kn  
MNP Extended Services 
(Not available in V.22bis) 
Values:  
 
= 0, 1, 2.
 
Default:  
 
Description:  
 
Enables or disables conversion of a V.42 LAPM connection to an MNP 10 connection. 
 
 
The parameter value, if valid, is written to S40 bits 0 and 1. 
 
 
–K0   Disables V.42 LAPM to MNP 10 conversion. (Default.) 
 
 
–K 1   Enables V.42 LAPM to MNP 10 conversion. 
 
 
–K 2   Enables V.42 LAPM to MNP 10 conversion; inhibits MNP Extended Services initiation 
during V.42 LAPM answer mode detection phase. 
 
 
 
Command:  
–STEn  Set Telephony Extension 
Values:  
 
= 0 or 1
 
Default:  
 
Description:  
 
The –STE command enables/disables Line-In-Use, Extension Pickup, and Remote 
  
Hangup 
detection 
features. 
 
 
Note
: This command is supported only if enabled through firmware configuration.  
 
 
Defined Values:
   <value> Decimal number corresponding to the selected bit-mapped 
 
  options. The bit field are defined as follows: 
 
 
Bit 0 = Line-In-Use detection enable/disable. 
 
 
Bit 1 = Extension Pickup detection enable/disable. 
Bit 2 = Remote Hangup detection enable/disable. 
<value> 
(Dec.)
 
Remote 
Hangup
 
Extension 
Pickup
 
Line-in-Use
 
(default) 
Disabled Disabled Disabled 
Disabled Disabled Enabled 
2 Disabled 
Enabled 
Disabled 
3 Disabled 
Enabled 
Enabled 
4 Enabled 
Disabled 
Disabled 
5 Enabled 
Disabled 
Enabled 
Enabled Enabled Disabled 
Enabled Enabled Enabled 
Reporting Current or Selected Values 
Command: -STE? 
Response: -STE: 
<value> 
Example: 
-STE: 4  Remote Hangup enabled, Extension Pickup disabled, and 
Line-In-Use disabled 
Reporting Supported Range of Parameter Values
 
Command: 
-STE=?  Show available options 
Response: -STE: 
0-7 
Result Codes:  OK <value> = 0-7; ERROR otherwise. 
Behavior in Data Mode 
When on-hook, if the line is in use and an ATDT is issued, the modem will not go off-hook 
and will return with the message LINE-IN-USE. 
When off-hook and either an extension is picked up or a line reversal is detected, the 
modem will drop the connection.  The disconnect reason in register S86=25 (this is also 
defined for #UD).  The user must flash the hook in order to get a dial tone due because the 
remote server will be retraining. 
If the local handset is picked up while the modem is off-hook, the modem will do a link-
disconnect, flash the hook for 1.5 seconds, then connect the local handset to the line.  At 
this point, the user dial tone should be on the local handset. The disconnect reason in 
S86=25. 
Operation in Data Mode 
Line-In-Use (Enabled by AT-STE=1, AT-STE=3, AT-STE=5, or AT-STE=7) 
Case 1: Telephone Line is in Use 
If an ATDT, ATDP or ATDL is issued while Line-In-Use detection is enabled and the 
telephone line is in use, the modem will immediately return the message LINE-IN-USE 
to the DTE without going off-hook, and then return to command mode.  
Case 2: Telephone Line is in Use But Disconnected 
If an ATDT, ATDP or ATDL is issued while Line-In-Use detection is enabled and the 
telephone line is NOT in use, the modem will go off-hook after a short pause, then 
respond with CONNECT or NO CARRIER message.