Multi-Tech Systems MT3334HD8 ユーザーズマニュアル

ページ / 100
MT3334HD8 User Guide
86
CommPlete Communications Server
Changing the Passwords
  1.  Establish a remote configuration link with the remote modem as described above.
  2.  Type AT#IMULTI-TECH (or AT#Ixxxxxx if you have replaced the MULTI-TECH password with
xxxxxx) and press E
NTER
. The modem responds with OK
 if the login password is correct, and
ERROR
 if it is wrong.
  3.  Type AT#SMODEMSETUP (or AT#Syyyyyy if you have replaced the MODEMSETUP password
with 
yyyyyy) and press E
NTER
. The modem responds with OK
 if the setup password is correct, and
ERROR
 if it is wrong.
  4.  To change the login password, type AT#I=xxxxxx, where xxxxxx stands for the password, and
press E
NTER
. The password may include any keyboard characters, but must be six to ten characters long.
The modem responds with 
OK.
  5.  To change the setup password, type AT#S=yyyyyy, where yyyyyy stands for the password, and
press E
NTER
. The password may include any keyboard characters, but must be six to ten characters
long. The modem responds with 
OK.
  6.  The new passwords are saved automatically. You may now either enter more AT commands or exit
remote configuration with ATO<CR>. The next time you remotely configure the modem you must
use the new setup password.
Note: 
 Passwords are case sensitive. The next time you enter the password, it must be in the same case as
you set it up.
Changing the Remote Escape Character
To increase security, you may wish to change the remote modem’s remote configuration escape character.
The remote configuration escape character is stored in register S13. The factory default is 37, which is the
ASCII code for the percent character (%). Setting S13
 to 0 (zero) will disable remote configuration
entirely—but if you do this remotely, you won’t be able to change it back remotely!
  1.  Establish a remote configuration link with the remote modem as described above.
  2.  Type ATS13=n, where n is the ASCII code for the new remote configuration escape character, then
press E
NTER
.
  3.  Save the new value by typing AT&W and pressing E
NTER
.
  4.  Type ATO<CR>, then 1, to exit remote configuration.