Multi-Tech Systems MT2834BA Series ユーザーズマニュアル

ページ / 120
84
Chapter 8 - Dip-Switch Settings
Multi-Tech Systems, Inc. MT2834BA/BL Series User Guide
8.4
Recording Option Configurations
This section lets you record any changes you may have made to the DIP-Switch settings. Circle the
appropriate setting and record the effect for future reference.
DIP-Switches
Switch
Function
Position
Effect
#1
Force DTR/DTR from Interface*
UP*
DTR Dependent on Interface
DOWN
DTR Forced On at All Times
#2
Flow Control &E4*/&E5
UP*
Hardware Flow Control
(Async/Dial-Up/Leased Line)
DOWN
XON /OFF Flow Control
#2
SDLC*/BSC (Sync)
UP*
SDLC Mode On
DOWN
BSC Mode On
#3
Result Codes Enable*/Disable
UP
Command Mode Response Off
(Async/Dial-up)
DOWN*
Command Mode Response ON
#3
DbM Transmit 
(-9db/0dB)
*/
(-15db/-10dB)
UP
-15 dB Transmission (leased line)
(Async/Sync/Lease-Line)
DOWN*
  -9 dB Transmission (leased line)
#4
UUCP Enable/Disable*
UP*
UUCP Spoofing Off
(Async/Dial-Up/Leased Line)
DOWN
UUCP Spoofing On
#4
AS/400 Enable/Disable*
UP*
AS/400 Mode Off
(Sync/Dial-Up/Leased line)
DOWN
AS/400 Mode On
#5
Auto-Answer Enable*/Disable
UP*
Automatic Answer On
(Async/Sync/Dial-Up)
DOWN
Automatic Answer Off
#5
Answer*/Originate
DOWN
Answer Mode On
(Async/Sync/Leased Line)
UP*
Originate Mode On
#6
Max-Thru Enable*/Disable
UP*
Max Throughput On
(Async/Dial-Up/Leased)
DOWN
Max Throughput Off
#6
Slave Clock Enable/Disable*
UP*
Slave Clocking Off
(Sync/Dial-Up/Leased)
DOWN
Slave Clocking On
#7
RTS/Normal/Forced*
UP
RTS Dependent on Interface
(Sync/Async/Dial/Leased)
DOWN*
RTS Forced On at All Times
#8
Command Mode Enabled*
UP
Command Mode Off
(Sync/Async/Dial/Leased)
DOWN*
Command Mode On
#9
Local/Remote* LoopBack
UP
Local Digital Loopback On
(Async/Sync/Dial/Leased)
DOWN*
Remote Digital Loopback On
#10
Dial-Up*/Leased-Line
UP*
Dial-Up Operation
DOWN
Leased-Line Operation
#11
"AT"/"Multi-Tech" Result Codes*
UP
AT Responses
(Asynchronous)
DOWN*
Multi-Tech Responses
#11
Internal Clocking*/External Clocking
UP
External Clocking Selected
(Synchronous)
DOWN*
Internal Clocking Selected
#12
Sync/Async Mode*
UP
Synchronous Mode On
DOWN*
Asynchronous Mode On
* Factory Default Setting