Command: 
+IFC 
 DTE-Modem Local Flow Control 
Values: 
 
0, 1 
 
 
Values defined by 
<
modem_by_DTE
> 
S
pecifies the method to be used by the DTE to control 
the flow of received data from the modem. 
 +IFC0 
 
None 
 
 
 
+IFC1   XON/XOFF on transmitted data (XON/XOFF on transmit data); do not pass 
XON/XOFF characters to the remote modem. 
 
+IFC2   Circuit 133 (Ready for Receiving). 
 
+IFC3   DC1/DC3 on circuit 103 (Transmitted Data) with DC1/DC3 characters being 
passed through to the remote DCE in addition local flow control applied. 
 
 
Values defined by 
<
DTE_by_modem
> 
Specifies the method to be used by the modem to control 
the flow of transmitted data from the DTE. 
 +IFC0 
 
None. 
 
 
+IFC1   XON/XOFF on received data. 
 +IFC2 
 
CTS/RTS. 
 
 
Reporting Current or Selected Values
 
Command: +IFC? 
 
 
Reporting Supported Range of Parameter Values
 
Command: +IFC=? 
 
Command: 
+ILRR   DTE-Modem Local Rate Control
 (Not available in V.22bis) 
Values: 
 
0, 1 
Default:   0 
Description: 
This extended-format numeric parameter controls whether or not the extended-
format +ILRR:<rate> information text is transmitted from the modem to the DTE. 
 
 
+ILRR0 
Disables reporting of local port rate (+ILRR: is not transmitted).  
 
 
+ILRR1 
Enables reporting of local port rate (+ILRR: is transmitted). 
 
 
Reporting Current or Selected Values 
  
 
Command: 
+ILRR? 
 
 
Reporting Supported Range of Parameter Values 
  
 
 
Command: 
+ILRR=? 
  
Reported 
Rate 
  
The <rate> reported represents the current (negotiated or renegotiated) DTE-modem rate. If 
enabled, the intermediate result code is transmitted after any modulation, error control or 
data compression reports are transmitted, and before any final result code (e.g., CONNECT) 
is transmitted. The <rate> is applied after the final result code is transmitted. 
 
 
The DTE-modem port rate will change only if neither buffered mode nor error controlled 
means are enabled (+ES=x,0) and if the negotiated carrier rate (+MRR) does not match the 
current DTE-modem port rate (auto-detected from the previous command line). 
 
 
Defined Values: 
 
 
<rate>  
Decimal value representing the current (negotiated or renegotiated) DTE-modem 
rate: 0, 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, or 230400 
 
<rx_rate> 
Optional decimal value reporting the RXD rate, if it is different from the TXD rate: 0, 
300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, or 230400 
 
 
 
Command: 
+IPR 
Fixed DTE Rate 
(Not available in V.22bis) 
Values: 
 
n/a 
Description: 
 
This numeric extended-format parameter specifies the data rate at which the modem will 
accept commands during online operation. It may be used to select operation at rates at 
which the modem is not capable of automatically detecting the data rate being used by the 
DTE. Specifying a value of 0 disables the function and allows operation only at rates 
automatically detectable by the modem. The specified rate takes effect following the 
issuance of any result code(s) associated with the current command line. 
The <rate> specified does not apply in Online Data State if Normal Mode (Direct Mode) of 
operation is selected. 
Defined Values: 
 <rate>
  Specifies the DTE-modem interface operation rate in bits/s. The available rates 
are: 0, 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, or 230400 
 
If unspecified or set to 0, automatic detection is selected and the character 
format is also forced to auto-detect, +ICF=0. 
If the rate specified is not supported by the modem, an ERROR result code will 
be returned. 
Reporting Current or Selected Values 
Command: +IPR? 
Reporting Supported Range of Parameter Values 
Command: +IPR=?