SNTP Client Commands – Setup 
 
Command Syntax 
set sntp-client polling-time <value> 
where 
value = 2 to 1440 
Description 
Sets the polling time at which SNTP client requests the server to update the 
time. 
Default Value 
300 
Success 
OK 
Error 
1. Invalid 
arguments 
"error: Invalid Polling time" 
2.  Too few arguments 
“Usage: set sntp-client polling-time <value> 
Type set sntp-client polling-time ? for more information” 
 
Command Syntax 
set sntp-client daylight-saving <enable/disable> 
Description 
Enables/Disables the Day Light Saving Mode. 
Default Value 
Enable 
Success 
OK 
Error 
1. Invalid 
arguments 
"error: Invalid parameter" 
2.  Too few arguments 
“Usage: set sntp-client daylight-saving <enable/disable> 
Type set sntp-client daylight-saving ? for more information” 
 
Command Syntax 
set sntp-client daylight-saving offset <+/-value> 
where 
value = 0 to 120 minutes 
Description 
Sets the offset to use during the Day Light Saving Mode. 
Default Value 
60 
Success 
OK 
Error 
1. Invalid 
arguments 
"error: Invalid offset value" 
2.  Too few arguments 
“Usage: set sntp-client daylight-saving offset <value> 
Type set sntp-client daylight-saving offset ? for more information” 
 
Command Syntax 
set sntp-client daylight-saving start-ordinal <string> 
where 
 string = first/second/third/forth/last 
Description 
Sets the start ordinal to use during the Day Light Saving Mode. 
Default Value 
First 
Success 
OK 
Error 
1. Invalid 
arguments 
"error: Invalid start ordinal" 
2.  Too few arguments 
“Usage: set sntp-client daylight-saving start-ordinal <string> 