AT Commands for the Conexant Modem
 ION 7500 / ION 7600 User’s Guide
Page 288
Modem AT Commands Technical Note
AT+MS Commands Select Modulation
Selects the modulation; enables or disables auto-mode; specifies the lowest and 
highest connection rates; selects m-Law or A-Law codec type, and enables or 
disables robbed bit signaling generation (server modem) or detection (client 
modem).
+MS= <Mod> [,[<Automode>]  [,[<Min_Rate>] [,[<Max_Rate>] [,[<X_Law>]
[,[< Rb_Signaling>]]]]]] <CR>
AT+MS=? Send a string of information to the DTE consisting of supported 
options
\Nn
Operating Mode
AT\N0
Normal speed buffered mode
AT\N1
Serial interface
AT\N2
Reliable (error-correction) 
mode
AT\N3
Auto reliable mode
AT\N4
LAPM error-correction mode
AT\N5
MNP error-correction mode
<mod>
Modulation
Possible Rates (bps)
0
V.21
300
1
V.22
1200
2
V.22 bis
2400, 1200
3
V.23
1200
9
V.32
9600, 4800
10
V.32 bis
14400, 12000, 9600, 7200, 4800
11
V.34
33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 
14400, 12000, 9600, 7200, 4800, 2400
64
Bell103
300
69
Bell212
1200
Command Group
Members
Description