Multi-Tech Systems CF220 ユーザーズマニュアル

ページ / 84
Chapter 2:  Sample System  
Multi-Tech Systems, Inc. 
CF220 CallFinder User Guide 
13 
Step 2 Technical: Enter operating parameters of DID lines. 
Each DID line has 3 user-specified technical parameters.  You set them in the CallFinder software.   
 
Power
48Vdc
Channel 2
Channel 1
Power
5Vdc
Ethernet
FXS/FXO   DID
FXS/FXO   DID
10/100
Channel Configuration: Channel 1
Max DID Digits
4
DID Start
  wink
  immediate
  delay dial
Extension Port
  FXS
  FXO
Auto Attendant Delay
0
Receive Gain       100
Transmit Gain               100
Polarity
 
 
A
 
 
B
Update
Channel Configuration: Channel 2
Max DID Digits
4
DID Start
  wink
  immediate
  delay dial
Extension Port
  FXS
  FXO
Auto Attendant Delay     2
Receive Gain       100
Transmit Gain               100
Polarity
 
 
A
 
 
B
Update
CF
220
(Rear)
Telco
DID
Outlet
Telco
DID
Outlet
of DID Line
Technical Parameters
 
 
Technical Parameters Related to DID Line 
Parameter Value  Comments 
Max DID Digits 
Number of digits received on DID line. 
Polarity 
try A 
This is a trial-and-error setting. The DID line is a 
twisted pair. Only when installed can you know 
polarity. You determine the polarity by performance – 
with wrong polarity, connections cannot be made. 
DID Start 
ask telco 
Start mode varies with different implementations of 
DID.