Multi-Tech Systems CF220 ユーザーズマニュアル

ページ / 84
Chapter 4:  CallFinder Server Operation 
Multi-Tech Systems, Inc. 
CF220 CallFinder User Guide 
47 
Chapter 5 – CallFinder Server 
Operation 
 
Front Panel LEDs 
Label 
Identifier 
Name 
Description 
General LEDs 
 
 
Power 
On if unit is on. 
 
Status 
Flashing Green = unit is functioning properly 
Solid Red = unit is having its software updated. DO NOT 
TURN OFF if Status LED is solid red. 
Off = system is booting or power is off 
Line 1 LED 
Presents status of Channel 1. 
TD 
Transmit Data 
Channel 1 is being configured. 
RD 
Receive Data 
Channel 1 is reporting. 
TR 
Terminal Ready 
When lit, channel 2 is ready to receive a call. 
Lit when DTR to DID modem is high. 
DID 
DID 
The telco central office is drawing power from the DID line 
which means that a call is in progress. 
Line 2 LEDs 
Presents status of channel 2. 
TD 
Transmit Data 
Channel 2 is being configured. 
RD 
Receive Data 
Channel 2 is reporting. 
TR 
Terminal Ready 
When lit, channel 2 is ready to receive a call. 
Lit when DTR to DID modem is high. 
DID 
DID 
The telco central office is drawing power from the DID line 
which means that a call is in progress. 
Ethernet LEDs 
 
ACT 
Activity 
Lit when  packets are being transmitted by any device on the 
Ethernet network (not necessarily by the CallFinder). 
LINK 
Data Link 
Lit when a physical link has been established with the 
Ethernet network. 
SPEED 
Data Rate 
Indicates speed of Ethernet connection.  If lit, data rate is 100 
Mb/sec; if not lit, data rate is 10 Mb/sec. 
 
Updating CallFinder Firmware 
Successive editions of CallFinder firmware will be issued over time. There are two kinds of CallFinder 
firmware: (1) server firmware, and (2) firmware used by the DID-channel modems.  When issued, such 
updated firmware files will be accessible on the MultiTech web site.  However, updating is done by the 
FaxFinder/CallFinder Manager software.  To install updated firmware, see “Updating Firmware” in 
Chapter 7: FFCF Manager Operation