4.21 Switching channels by sending RS232 data
You can switch the SmartView XPro remotely by sending RS232 data to the serial
communications port (located on the rear panel adjacent to the power connectors).
All data should be sent using the following RS232 protocol.
Baud: 19200, bits: 8, stopbits: 1, parity:none
No handshaking is implemented but valid command characters will be echoed back
to the sender.
The top nibble (4 bits) of the command byte defines the user port that is to be
switched (1=port 1, 2=port 2, 3=port 3 and 4=port 4). The bottom nibble defines the
computer port that the user port is to be switched to (e.g. 0=port 1, 1=port 2, E=port
15, F=port 16).
For example:
Hexadecimal code 
14 switches user port 1 to computer port 5
Hexadecimal code 
38 switches user port 3 to computer port 9
Hexadecimal code 
4D switches user port 4 to computer port 14
Special codes are:
Hexadecimal code 
71 switches user port 1 to computer port 0 (off)
Hexadecimal code 
72 switches user port 2 to computer port 0 (off)
Hexadecimal code 
73 switches user port 3 to computer port 0 (off)
Hexadecimal code 
74 switches user port 4 to computer port 0 (off)
The 9-pin female RS232 connector at the rear of the SmartView has the following
pinout: