Testing
LTPH-UM-1109-01, Issue 1
52
January 9, 2002
H2TU-C-231 List 2
T
ESTING WITH
H2TU-C BERT G
ENERATOR
The H2TU-C BERT Generator screen allows transmission of a selected test signal from the H2TU-C towards
either the network (NET) or customer (CPE). Bit error rates are calculated and display on the Monitor screen.
1
Press
to select the Config menu.
2
Use the
and
arrow keys to select BERT Generator, then press
.
3
Use the arrow keys to select an option and press the
to cycle through the settings. Refer to
for a list of BERT generator option settings.
4
Press
to activate your choice.
5
To view BERT status, press
twice, then use the
arrow key to select the Monitor menu.
6
Press
. You can exit the status screen while signal generation is active.
Figure 29.
H2TU-C BERT Generator Screen
It is not recommended using the Bit Error Rate Tester from the remote and line unit at the same
time.
Table 19.
BERT Signal Generator Option Settings
Option
Description
BERT Signal Generator
Enabled (ENA) or Disabled (DIS)
BERT Signal Pattern
1:7 pattern, 2:8 pattern, 3:24 pattern, 2
23-1
 pseudo random, 2
20-1
 
pseudo random, 2
15-1
 pseudo random 
BERT Signal Linecode
AMI or B8ZS
BERT Signal Direction
Toward CPE or toward NET
BERT Interval
5 minutes, 60 minutes, Continuous (default)
C
ENTER
SPACEBAR
ENTER
ESC
ENTER
Monitor
Performance
Event Log
Config
Inventory
Report
Rlogon
Help
+----------------------+
| Standard Options ->
|
| ADC Options
->
|
|
BERT Generator
->
|
+--------------------------------------+
| BERT Signal Generator
:
ENA
|
| BERT Signal Pattern
: 1 in 7
|
| BERT Signal Linecode
: AMI
|
| BERT Signal Direction
: NET only
|
| BERT Interval
: Continuous
|
+--------------------------------------+
Use <Spacebar> to cycle through option settings and <Enter> to activate
ID: xxxx—-xxxx—-xxxx--xxxx
09/01/2001 12:30:01
H2TU-C
System: OK
___