Link Quality 
Receiving AP link quality on infrastructure networking mode 
Signal Strength 
Receiving AP signal strength on infrastructure networking mode 
 
5. REGULATION COMPLIANCE 
Compliant with   
 
 
FCC Part 15 Class B and C 
 
 
ETSI EN 300 328-2 and ETSI EN 301 489-1, -17, EN60950, CE-Mark 
 
 
Telec (Japan, Customized) 
   WiFi 
Compliant 
 
6. Environmental Requirement 
6.1. Drop and Vibration   
6.1.1. Anti-Static Voltage 
 
 
Static voltage tests by 4 kV in card frame should not cause system fail 
 
 
 
6.1.2. Vibration Test 
 
The vibration test is under the frequency and amplitude 10-25 Hz 1mm in vertical and horizontal direction by 30 
minutes that should not cause any damage on product
 
 
6.1.3. Package Drop Test 
 
Dropping the package from the height of 50cm for each of the six(6) faces onto the hard-wood floor should not cause 
any damage on product. 
 
6.2. Operation Environment 
 6.2.1. 
Temperature 
Range 
 
 
Operating:  
 
-0℃ - +55℃ (Except RF output power and sensitivity) 
  Storage: 
  -20℃ - +70℃ 
 
 6.2.2. 
Reliability 
Test 
 
One cycle of reliability test is keeping at -30℃ by 2 hours, switching temperature up to +60℃ within one hour , and 
testing at +60℃ by 2 hours, and switching temperature to -30℃ within one hour. Three cycle should be tested and 
without any product fail.   
 
 6.2.3. 
Humidity 
 
 
Operating:   
 
0% to 70%