Lucent Technologies PortMaster ユーザーズマニュアル

ページ / 364
Using ISDN BRI
12-15
ISDN BRI Unnumbered IP Configuration Example
Note – Configuring the maximum ports setting to a value higher than 0 causes the 
PortMaster to dial out to a continuous location, or become available for dial-out to an 
on-demand location. By configuring the maximum ports setting last, you ensure that 
the PortMaster will not attempt to make a connection with a location until you have 
configured all the settings for that location. 
After you configure location table settings as shown in Table 12-7, enter the following 
command to save the configuration:
Command> save all
For more information about configuring location table parameters, refer to Chapter 8, 
“Configuring Dial-Out Connections.”
Configuring the PortMaster in San Francisco
The PortMaster in San Francisco is being configured for an ISDN dial-up connection to 
the PortMaster in Denver.
IPX network
set location sf ipxnet F3
RIP routing
set location sf rip on
MTU
set location sf mtu 1500
Idle timer
set location sf idle 2
Dial group
set location sf group 2
Username
set location sf username sf
Telephone number
set location sf telephone 5551212
Password 
set location sf password anypasswd
High-water mark
set location sf high_water 0
Maximum ports
set location sf maxports 1
Table 12-7
Location Table Values (Continued)
Setting
Command