Lantronix 900-422 ユーザーズマニュアル

ページ / 87
11: Monitor Mode 
 XPress DR+ User Guide 
72 
Table 11-1. Monitor Mode Commands 
Command 
Command Name 
Function 
VS x.x.x.x 
Version 
Queries software header record (16 bytes) of unit 
with IP address x.x.x.x. 
GC x.x.x.x 
Get Configuration 
Gets configuration of unit with IP address x.x.x.x as 
hex records (120 bytes). 
SC x.x.x.x 
Send Configuration 
Sets configuration of unit with IP address x.x.x.x 
from hex records. 
PI x.x.x.x 
Ping 
Pings unit with IP address x.x.x.x to check device 
status. 
AT 
ARP Table 
Shows the unit’s ARP table entries. 
TT 
TCP Connection 
Table 
Shows all incoming and outgoing TCP connections. 
NC 
Network Connection 
Shows the unit’s IP configuration. 
RS 
Reset 
Resets the unit’s power. 
QU 
Quit 
Exits diagnostics mode. 
G0, G1, ....,Ge, Gf 
Get configuration 
from memory page 
Gets a memory page of configuration information 
from the device. 
S0, S1,...,Se, Sf 
Set configuration to 
memory page 
Sets a memory page of configuration information 
on the device. 
GM 
Get MAC address 
Shows the unit's 6-byte MAC address. 
SS 
Set Security record 
Sets the Security record without the encryption key 
and length parameters. The entire record must still 
be written, but the encryption-specific bytes do not 
need to be provided (they can be null since they 
are not overwritten). 
Responses to some of the commands are in Intel Hex format. 
Note:
 Entering any of the commands listed above generates one of the following 
command response codes: 
Table 7-2. Command Response Codes 
Response 
Meaning 
0> 
OK; no error 
1> 
No answer from remote device 
2> 
Cannot reach remote device or no answer 
8> Wrong 
parameter(s) 
9> Invalid 
command