Motorola PTP 600 Series ユーザーズマニュアル

ページ / 246
 
 
59
7.7.6 
Grounding the Installation  
The Outdoor Unit (ODU) must be properly grounded to protect against power surges. It is the 
user’s responsibility to install the equipment in accordance with Section 810 of the National 
Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the Canadian Electrical Code or the 
National Electrical Code in the country of installation. These codes describe correct 
installation procedures for grounding the outdoor unit, mast, lead-in wire and discharge unit, 
size of grounding conductors and connection requirements for grounding electrodes. It is 
recommended that installation of the outdoor unit be contracted to a professional installer. 
See Section 10 “Lightning Protection” for recommended grounding kits”. 
7.7.7 
Making the ODU Connection at the PTP 600 Series Bridge PIDU Plus  
The ODU is connected to the PIDU Plus by means of a concealed RJ45 connector. The RJ45 
connection has been placed inside the PIDU Plus hinged cover to prevent the user from 
inadvertently plugging other equipment into the ODU RJ45 socket.  
Warning: Plugging other equipment into the ODU RJ45 socket may damage the equipment 
due to the non-standard techniques employed to inject DC power into the 1000BaseT 
connection between the PIDU Plus and the ODU. Plugging the ODU into other equipment 
may damage the ODU and/or the other equipment.  
 
Step 1: Undo the retaining screw and hinge 
back the cover. 
 
Step 2: Plug in the ODU into the PIDU Plus 
Cable ensuring that it snaps home