Multi-Tech Systems GPRS (MTMMC-G) ユーザーズマニュアル

ページ / 203
Chapter 5 – Call Control Commands 
Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I) 
24 
 
Incoming Call Bearer   +CICB 
Description: 
This command sets the type of incoming calls when no incoming bearer is given (see +CSNS). 
 Note:
   Setting the +CICB command affects the current value of +CSNS. 
Values: <mode> 
 
 
0 Data 
  
Speech 
Syntax:    
AT+CICB=<mode> 
Command 
Possible responses
AT+CICB=2 
Note: If no incoming bearer, force a voice call
OK 
Note: Command accepted  
AT+CICB? 
Note: Interrogate value 
+CICB: 2 
OK 
Note: Default incoming bearer: voice call 
AT+CICB=? 
Note: Test command 
+CICB: (0-2) 
OK 
Note: Speech or data default incoming bearer 
 
 
Single Numbering Scheme   +CSNS 
Description: 
Selects the bearer to be used when an modem single numbering scheme call is set up (see +CICB). 
 Note:
 Setting the +CSNS command affects the current value of +CICB. 
Values: <mode> 
 
 
0   Voice 
 4 
  Data 
Syntax:   
AT+CSNS 
Command 
Possible responses
AT+CSNS=0 
Note: force a voice call OK
Note: Command accepted  
AT+CSNS? Note: 
Interrogate value +CSNS: 0
Note: Default incoming bearer: voice call
AT+CSNS=? 
Note: Test command
+CSNS: (0,2,4) Note: Voice or data default incoming 
bearer 
 
 
Gain Control   +VGR, +VGT 
Description: 
This command is used by the application to tune the receive gain of the speaker and the transmit gain 
of the microphone.  
Values:   
<Rgain> is the reception gain 
 
<Tgain> is the transmission gain 
Syntax:  
AT+VGR=<Rgain>  and    AT+VGT=<Tgain> 
Command 
Possible responses
AT+VGR=25 
 
OK 
Note: Command valid
AT+VGT=45 OK
Note: 
Command valid
AT+VGR? 
Note: Interrogate value 
+VGR: 128
OK 
Note: Default receive gain 
AT+VGR=? 
Note: Test command 
+VGR: (0-255)
OK Note: 
Possible 
values 
AT+VGT? 
Note: Interrogate value 
+VGT: 32
OK 
Note: Default transmit gain 
AT+VGT=? 
Note: Test command 
+VGT: (0-255)
OK Note: 
Possible 
values 
Note: 
For the 
AT+VGT? command with controller 1, the value is the lower value of range; whereas, 
with controller 2, the value corresponds to the entered value using AT+VGT=xx.