ALTINEX MT100-108 ユーザーズマニュアル

ページ / 7
MULTI-TASKER
400-0401-001
5
INSTALLING YOUR MT100-108
5
Step 1. Connect the power entry connector of the 
MT100-108  to the power outlet with the 
provided power cord. The power supply is 
universal and will work throughout the 
world with voltages from 110V-240VAC.
Step 2. If a control system is used to control the 
cards in the MT100-108, connect the 
RS-232 port of the  MT100-108 to the 
control system's RS-232 port. See 
Table 4.
Connector on
Multi-Tasker™
Computer or 
Control System
GND (Ground)
Ground
RXD (Receive)
Transmit
TXD (Transmit)
Receive
Table 4. MT100-108 RS-232 Control
NOTE: Make sure the transmit pin of the control 
unit is connected to the receive pin of the 
MT100-108 and that the receive pin of the 
control unit is connected to the transmit 
pin of the MT100-108. See Figure 1 and 
Figure 2.
Step 3. The unit is now operational.
OPERATION
6
The  MT100-108, along with the MT101-115 front 
panel, has many advanced remote control 
capabilities, which are accessible through standard 
RS-232 communication. The controlling can be 
accomplished through a computer, a control 
system, or any device capable of sending RS-232 
commands. The factory settings for the RS-232 
port are 9600 baud, 8 bits, 1 stop, and No parity. 
Commands used for MultiTasker cards such as 
[ON], [OFF], and [IO] that end in "S" will be saved 
to memory. Commands not ending in "S" will still be 
executed but will not be restored when the system 
is reset (power off & power on again).
In this section, "Basic Enclosure" or "Unit" has the 
same meaning. The basic enclosure is a complete 
and independent card cage that has a controller 
and 12 slots for plug-in cards. Each unit or basic 
enclosure has its own Unit ID that is based on a 
number from 0 to 9. Each plug-in card also has its 
own Card ID that is a number from 1 to 12.
6.1 RS-232 CONNECTION
If a control system is used to control the cards in 
the MT100-108 Multi-Tasker™ Basic Enclosure, 
connect the RS-232 connector of the 
MT100-108 to the control system's RS-232 port. 
To connect the Multi-Tasker™ (MT) to a 
computer or a terminal, you must have the 
proper interface cable.
The RS-232 cable must have the appropriate 
connector on each end and the internal wiring 
must be correct. Connectors typically have 9 
pins (DB-9 connector) or 25 pins (DB-25 
connector) with a "male" or "female" pin 
configuration.  See Figures 1 and 2 for pinout 
details.
Figure 1
DB9 Serial Connection
Figure 2
DB25 Connection