Nokia CC100 ユーザーズマニュアル

ページ / 56
CC100Master Bridge User’s Guide 
Master/Smart EP Ethernet Properties (Ether) 
The Ethernet properties of the Master device and Smart EP device are configurable. For those EPs equipped with the 
fixed Ethernet properties are remarked as un-configurable EPs – usually based on 3010 chipset. 
 
Port Setup 
To configure built-in Ethernet switch port properties, including speed, flow control, and maximum In/Out rate 
(bandwidth control) of ports LAN1/LAN2/HCNA. 
 
 
Service and Speed/Duplex 
Change ‘Service’ to enable or disable the port. This setting opens or closes the related Ethernet switch port in EP’s. 
The default setting in the field ‘Speed/Duplex’ is ‘
Auto
’ which states for auto-negotiation. 
 
Bandwidth Control 
Consider port HCNA as the network backbone and refer to the following diagram to set up bandwidth control 
parameters in the EP’s Ethernet switch (Regarded as Hardware bandwidth control, works for both upstream and 
downstream). The maximum allowed rate should be the setting value multiplied by 64Kbps.  If maximum rate 
exceeds 100Mbps (as the value 1563), there will be no bandwidth control at all.  
14