Nokia CC100 ユーザーズマニュアル

ページ / 56
CC100Master Bridge User’s Guide 
 
You can also use other Combiner’s or Mixer-Splitter’s with the CC100 to build the same system. See the following 
Figure 3 for different cabling. 
 
 
Figure 3: Different Cabling of CC100
 
 
NOTE: After powering up the CC100, the LED ‘SynMode’ will always be glowing and LED ‘Link/Act’ will light 
up if at least one EP is detected on the HCNA network. A dimmed LED ‘Link/Act’ shows if no EP is attached to 
the HCNA network. 
 
NOTE: The minimum attenuation between Master and EP is 12dB.  The EP is usually connected to the coaxial 
cable via a Tap device that provides enough attenuation (contributes more than 20dB). If you intend to connect the 
Master and EP directly for test purposes, please add the attenuator that exceeds 12dB to the coaxial cable. 
 
Verification 
After you have finished the installation, you should be able to access the CC100 through Ethernet link.