Extron electronic dip hdmi ユーザーズマニュアル

ページ / 139
DXP DVI Pro and DXP HDMI Series • Operation
41
To perform a soft reset of the switcher:
1. 
Use a small Philips screwdriver to press and hold the rear panel Reset button until 
the front panel Video and Audio buttons blink once (for an events reset), twice (for a 
system reset), or three times (for an absolute reset).
 
I / O
VIDEO
AUDIO
RESET
RESET
RESET
I / O
AUDIO
RESET
RESET
RESET
I / O
VIDEO
AUDIO
RESET
RESET
RESET
Release, then 
immediately
press and release again.
VIDEO
Release, then 
immediately
press and release again.
IP Settings 
Reset
(Level 4)
6 seconds
Absolute Reset
(Level 5)
9 seconds
Press and 
hold 
the Reset button.
3 seconds
Events Reset
(Level 3)
Front panel I/O buttons flash 
once.
Reset LED flashes 
once.
Release, then 
immediately
press and release again.
Reset LED flashes 
twice.
Press and 
hold 
the Reset button.
Press and 
hold 
the Reset button.
Reset LED flashes 
three times.
Front panel I/O buttons flash 
twice.
Front panel I/O buttons flash 
three times.
Figure 61. 
Soft Resets
2. 
Release the Reset button and then immediately press and release the Reset button 
again. Nothing happens if the second momentary press does not occur within 
1 second.