RuggedCom RX1510 ユーザーズマニュアル

ページ / 45
3. Installation
RuggedCom® RuggedBackbone™
29
RX1510 Installation Guide Rev 104
3.11.1. Module Insertion – SFP
Special attention must be paid to the orientation of SFP modules upon installation in the RX1510
chassis. The figure below shows the proper orientation of SFP modules installed in both upper and
lower line modules. SFP modules on the upper row must be inserted top-side up. SFP modules
on the lower row must be inserted top-side down. SFP modules should be inserted with the bail-
latch in the locked position.
Figure 3.23. SFP module orientation
Figure 3.24. SFP module insertion
SFP  modules  should  slide  gently  into  their  ports  and  should  lock  in  place  when  fully  inserted.
Dust covers should be in place when installing the modules, and should always be in place when
cables are not connected.
3.11.2. SFP Module Removal
To  remove  the  SFP  module,  disconnect  any  cables  and  replace  the  dust  cover  to  protect  the
optics. Extend the bail latch found on the top of the module. Grasp the bail latch and gently pull
outwards to unlock and remove the module.
Immediately after removal, store the SFP module in an ESD-safe environment.