5. EMI And Environmental Type Tests
RuggedCom® RuggedBackbone™
42
RX1510 Installation Guide Rev 104
5. EMI And Environmental Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure Contact
+/- 8 kV
4
IEC 61000-4-2
ESD
Enclosure Air
+/- 15 kV
4
IEC 61000-4-3
Radiated RFI
Enclosure Ports
20 V/m
Note
a
Signal ports
+/- 4kV @ 2.5kHz
Note
a
D.C. Power ports
+/- 4kV
4
A.C. Power ports
+/- 4kV
4
IEC 61000-4-4
Burst (Fast Transient)
Earth ground ports
+/- 4kV
4
Signal ports
+/- 4kV line-to-earth,
+/- 2kV line-to-line
4
D.C. Power ports
+/- 2kV line-to-earth,
+/- 1kV line-to-line
3
IEC 61000-4-5
Surge
A.C. Power ports
+/- 4kV line-to-earth,
+/- 2kV line-to-line
4
Signal ports
10V
3
D.C Power ports
10V
3
A.C. Power ports
10V
3
IEC 61000-4-6
Induced (Conducted) RFI
Earth ground ports
10V
3
40 A/m, continuous,
1000 A/m for 1 s
Note
a
IEC 61000-4-8
Magnetic Field
Enclosure Ports
1000 A/m for 1 s
5
D.C. Power ports
30% for 0.1s, 60% for
0.1s, 100% for 0.05s
N/A
IEC 61000-4-29
Voltage Dips & Interrupts
A.C. Power ports
30% for 1 period,
60% for 50 periods
N/A
IEC 61000-4-11
Voltage Dips & Interrupts
A.C. Power ports
100% for 5 periods,
100% for 50 periods
N/A
Signal ports
2.5kV common, 1kV
diff. mode@1MHz
3
D.C. Power ports
2.5kV common, 1kV
diff. mode@1MHz
3
IEC 61000-4-12
Damped Oscillatory
A.C. Power ports
2.5kV common, 1kV
diff. mode@1MHz
3
Signal ports
30V Continuous, 300V for 1s
4
IEC 61000-4-16
Mains Frequency Voltage
D.C. Power ports
30V Continuous, 300V for 1s
4
IEC 61000-4-17
Ripple on D.C.
Power Supply
D.C. Power ports
10%
3
Signal ports
2kVAC (Fail-Safe Relay output)
N/A
D.C. Power ports
1.5kVDC
N/A
IEC 60255-5
Dielectric Strength
A.C. Power ports
2kVAC
N/A
Signal ports
5kV (Fail-Safe Relay output)
N/A
D.C. Power ports
5kV
N/A
IEC 60255-5
H.V. Impulse
A.C. Power ports
5kV
N/A
a
 RuggedCom-specified severity levels
Table 5.1. IEC 61850-3 EMI Type Tests