Agilent Technologies 20ET ユーザーズマニュアル

ページ / 478
2- 35
Making Mixer Measurements (Option 089 Only)
Phase or Group Delay Measurements
Phase or Group Delay Measurements 
For information on group delay principles, refer to 
Phase Measurements 
When you are making linear measurements, you must provide a reference for determining 
phase by splitting the RF source power and send part of the signal into the reference 
channel. (This does not work for frequency offset measurements, since the source and 
receiver are functioning at different frequencies.)
To provide a reference signal for the phase measurement, you need a second mixer. This 
mixer is driven by the same RF and LO signals that are used to drive the mixer under test. 
The IF output from the reference mixer is applied to the reference (R) channel of the 
analyzer.
Phase Linearity and Group Delay 
Group delay is the rate of change of phase through a device with respect to frequency 
(d
φ
/d
ω
). Traditionally, group delay has been used to describe the propagation delay (
τ
g
), 
and deviation from linear phase through a linear device. However, this parameter also 
contains valuable information about transmission delay and distortion through a 
non-linear device such as a mixer or frequency converter. For example, flat group delay 
corresponds to low modulation distortion (that is, carrier and sidebands propagate at the 
same rate).
Phase linearity and group delay are both measurements of the distortion of a transmitted 
signal. Both measure the non-linearity of a device’s phase response with respect to 
frequency.
In standard vector error-correction, a thru (delay=0) is used as a calibration standard. The 
solution to this problem is to use a calibration mixer with very small group delay as the 
calibration standard.