Siemens SM2 monitoring system ユーザーズマニュアル

ページ / 500
U3585-J-Z125-8-76
335
SM2 information screens
STATUS TABLE
REASON
Reason for the trace entry. In many cases (with TYPE=S-ER) this is
the name of the system function which reported an error.
CREATE:
Creation of task
TERM:
Termination of task
Subsystem-STA:
Start of subsystem use
Subsystem-STO:
End of subsystem use
Subsystem-NLD:
Subsystem not loaded
TYPE
MODUL
Abbreviated name of the SM2 module writing the trace entry
(without "NPS", "NPFS")
ID
Identifies the location at which the error occurred. In many cases
this is the offset within the module. If the error is unique within the
module, this field contains no entry.
CODE
Return code of the system function called (for TYPE=S-ER) or
additional information (for TYPE=I-ER) or zero
Note
The trace entries (particularly those with TYPE=I-ER,S-ER) are only relevant for SM2.
I-ER:
Internal error
(internal error during execution of SM2)
S-ER:
System error
(error calling a BS2000 system function)
TASK:
Task event
(start/end/crash of an SM2 task)
SS:
Subsystem event (start/end of subsystem use by SM2)