Siemens D410 ユーザーズマニュアル
Commissioning (software)
4.2 Configuring the system in offline mode
D410
Commissioning Manual, 08/2008 Edition
Commissioning Manual, 08/2008 Edition
65
3. Select your motor module by order number from the list shown in the "Power Unit" dialog
box.
Figure 4-3
Selecting a power unit
4. Select in the "Power unit supplementary data" dialog the component added to the power
unit.
The selection of the component depends on the construction type.
– D410 DP with D410 PN: The SIMOTION D410 snapped directly onto the PM340
– D410 DP with D410 PN: The SIMOTION D410 snapped directly onto the PM340
power module
– CUA31 or CUA32: The CUA3x snapped directly onto the PM340. The D410 is
mounted individually on a mounting plate. The D410 is connected with the CUA3x
using a DRIVE-CLiQ cable.