Alliance Laundry Systems NK120 ユーザーズマニュアル

ページ / 26
505942
9
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
A. Interface PC and Machines
1. The Data Connector should be attached to the 
network board on the back of the PC. The PC 
must be Pentium 166 or better, have 32 mb 
RAM minimum, a CD drive, a mouse and 
Windows 98 or higher.
2. Carefully strip 1/4" of the insulation from the 
black and red twisted pair wire. If too little 
insulation is stripped, and insulation is inside 
the connector, the network will not 
communicate. If too much is stripped, the wires 
will short. Refer to Figure 5.
3. The black/red twisted pair (Alliance Laundry 
Systems recommends using American 
Electronic Wire Co. part number 781816PFO - 
2Z) wires should be connected to slots 1 and 2 
(red from 1, black from 2). Refer to Figure 6.
B. Interfacing a Laptop to Machines
1. Attach the RS-485 cable to the Network Card 
and insert the card into the PCMCIA Slot on the 
laptop.
2. Attach the network cable to the  RS-485 cable.
3. Carefully strip 1/4" of the insulation from the 
black and red twisted pair wire. If too little 
insulation is stripped, and insulation is inside 
the connector, the network will not 
communicate. If too much is stripped, the wires 
will short. Refer to Figure 5.
4. Place a 120 
Ω
 1/2 Watt terminating resistor and 
2 560 
Ω
 1/4 Watt bias resistors into the terminal 
strip. Refer to Figure 3.
NOTE: One of the 560 
Ω 
1/4 Watt bias resistors 
connects between the white and red wires of the 
network cable. The other 560 
Ω
 1/4 Watt resistor 
connects between the black and green wires of the 
network cable.
Figure 1
NETWORK 
BOARD
DATA
CONNECTOR
BLACK AND RED
TWISTED PAIR
WIRE
BLACK
RED
Figure 2
COM112N
NETWORK
CABLE
TERMINAL
STRIP
RS-485
CABLE
NBS-20
CARD
COM112N