2  Page 2 of the setup menu- Alarm Setting
Push Setup buttons (#1, #2) simultaneously and push (#1) button again to display page 2 of the setup menu on the 
screen. This Alarm Setting menu is used to set the desired alarm confi guration like buzzer, V-loss alarm and V-loss relay.
11.5 Quad Display On-screen Menu 
 
Chapter 11
ALARM SETTING
CH
SENSOR
TYPE
STATUS
1
OPEN
NO
ON
2
OPEN
NO
ON
3
OPEN
NO
ON
4
OPEN
NO
ON
SENSITIVITY:
0.3 S
DURATION:
30 S
BUZZER: ON
V-LOSS ALARM:
ON
V-LOSS RELAY:
OFF
2.1 Sensitivity:  
The features are not applicable in these model.
2.2  Alarm Hold Duration: 
The features are not applicable in these model.
2.3 Buzzer: 
The device has a build-in buzzer to signal a detected alarm through sound. User can choose to disable the buzzer by 
setting it to OFF.
2.4 V-Loss Alarm:
This entry is used to enable or disable the video loss alarm. The device automatically detects loss of video at any input if 
this entry is set to ON. User can choose to disable this feature by setting it to OFF for applications like video conferenc-
ing or others that will need constant video source switching.
 
2.5 V-Loss Relay Control:
The device is equipped with an alarm controlled relay, which can be activated by both sensor trigged alarm and video 
loss alarm. This entry allows user to disable the relay activation from a loss of video in any camera input.
3  Save the settings and exit Setup Menu mode
Push (#1) button again will allow you to save the settings and go back to the normal operation mode and show a quad 
display on the screen.