Vidikron Vision 110 ユーザーズマニュアル

ページ / 88
Vidikron Vision Model 110 Installation/Operation Manual
41 
PRE
L
IMINAR
Y
Configure Lens Motor Trigger
CineWide with AutoScope maintains constant image height independent of the aspect ratio, 
while using the full display resolution of the projector. It accomplishes this by moving the 
anamorphic lens in front of the primary lens when widescreen material is being viewed. 
When the viewer transitions back to 16:9 or 4:3 source material, the anamorphic lens moves 
out of the light path.
To configure the lens motor trigger on the Vision 110 for proper AutoScope operation: 
 
1.
Project a 2.35:1 aspect ratio test pattern or other image on the screen. 
2.
Press MENU on the remote control and enter the Service menu passcode.
3.
Select Service from the Main menu. 
4.
Select Triggers from the Service menu. 
5.
Assign the trigger output to which the lens motor is connected to the Cinema and 
IntelliWide 2.35 aspect ratios. This enables the lens motor to move the anamorphic lens 
into position (in front of the primary lens) when either aspect ratio is selected. 
6.
To save the trigger settings, press 
 repeatedly to highlight “Save.” Then, press ENTER
7.
Select the Cinema aspect ratio to move the anamorphic lens into position, if it isn’t 
already. To do this, press CINEMA on the Vision 110 remote control (Figure 2-4), or press 
 or 
 repeatedly with no menus visible on-screen. 
Adjust the Anamorphic Lens
Adjusting the Horizontal (X) Lens Position: 
1.
Project a white field on the screen. 
2.
Loosen the Yaw/X-Adjustment Levers underneath the lens. 
3.
Slowly move the anamorphic lens into place so that there are no shadows on either side 
of the screen: 
 
4.
When the horizontal position is properly set, tighten the Yaw/X-Adjustment Levers to 
secure the lens in place.
Too Far Right
Too Far Left
Correct position