Sony VPL-FX35 ユーザーズマニュアル

ページ / 46
32
VPL-FX30
(5) Comm Error
Communication between Ethernet controller and main CPU has been failed.
Timeout
Timeout occurred.
Check Sum Error
A check sum error occurred.
Framing Error
A framing error occurred.
Parity Error
A parity error occurred.
Over Run Error
An overrun error occurred.
Other Comm Error
Another error occurred.
Unknown Response
The data cannot be processed was received.
(6) NVRAM Error
Read Error
Reading from NVRAM was failed.
Write Error
Writing to NVRAM was failed.
8. Packet 
Examples
For SETTING the picture mode to dynamic, the packet should be as follows. 
 
HEADER (VERSION, CATEGORY) = (02h, 0Ah)
 
COMMUNITY = “SONY” = (534F4E59h)
 
COMMAND (REQUEST, ITEM NO, DATA LENGTH) = (00h, 0002h, 02h)
 
DATA = 0000h
The same result can be obtained by using ENCAPSULATION mode as well.
 
HEADER (VERSION, CATEGORY) = (02h, 0Ah)
 
COMMUNITY = “SONY” = (534F4E59h)
 
COMMAND (REQUEST, ITEM NO, DATA LENGTH) = (00h, 7000h, 08h)
 
DATA (START CODE, ITEM NO, SET/GET, DATA, CHECK SUM, END CODE) 
 
= (A9h, 0002h, 00h, 0000h, 02h, 9Ah)
4-3-3. SNMP
The traditional SNMP is supported. By using this protocol, remote monitoring feature is provided.