Vivitek D91X ユーザーズマニュアル

ページ / 75
DLP Projector—User’s Manual 
 63  
A
PPENDIX 
RS-232C Protocol 
RS232 Setting
 
Baud rate: 
9600 
Parity 
check: 
None 
Data bit: 
Stop bit: 
Flow 
Control 
None 
Minimum delay for next command: 1ms 
Control Command Structure 
       
                
 
Header code 
Command code  Data code 
End code 
HEX 56H 
Command 
Data 0Dh 
ASCII ‘V’ 
Command Data CR 
Operation Command 
Note: 
XX=00-98, projector's ID, XX=99 is for all projectors 
Return Result P=Pass / F=Fail 
n: 0:Disable/1: Enable/Value(0~9999)  
  
Command Group 00 
ASCII HEX  Function 
Description 
Return 
Result
VXXS0001 
56h Xh Xh 53h 30h 30h 30h 31h 0Dh 
Power On 
 
 P/F 
VXXS0002 
56h Xh Xh 53h 30h 30h 30h 32h 0Dh 
Power Off 
 
 P/F 
VXXS0003 
56h Xh Xh 53h 30h 30h 30h 33h 0Dh 
Resync 
 
 P/F 
VXXG0004 
56h Xh Xh 47h 30h 30h 30h 34h 0Dh 
Get Lamp Hours 
 
 Pn/F 
VXXS0005n 
56h Xh Xh 53h 30h 30h 30h 35h nh 0Dh Set Air filter timer 
n=0~999999 
P/F 
VXXG0005 
56h Xh Xh 47h 30h 30h 30h 35h 0Dh 
Get Air filter timer 
n=0~999999 
Pn/F 
VXXS0006 
56h Xh Xh 53h 30h 30h 30h 36h 0Dh 
System Reset 
 
 P/F 
VXXG0007 
56h Xh Xh 47h 30h 30h 30h 37h 0Dh 
Get System Status 
0:Reset 
1:Standby 
2:Operation 
3:Cooling 
Pn/F 
VXXG0008 
56h Xh Xh 47h 30h 30h 30h 38h 0Dh 
Get F/W Version 
 
 Pn/F 
VXXG0009 
56h Xh Xh 47h 30h 30h 30h 39h 0Dh 
Get Alter EMail 
 
 Pn/F 
VXXS0009n 
56h Xh Xh 53h 30h 30h 30h 39h nh 0Dh Set Alter Email 
P/F