Draper 220V プリント

ページ / 2
220V Signature/Series E & V by Draper
Single Station Control
CE Approved
Terminal strip in
junction box at left
end of screen
Dashed wiring 
by electrician
Neutr
al
L1
230V, 
50 Hz.
Terminal strip in
junction box at left
end of screen
Dashed wiring 
by electrician
Neutr
al
Hot
Multiple Station Control
Not CE Approved
Cap off with wire
nut & tape
Red
Red
Red
Blue
Blue
Blue
Black
Black
230V, 50 Hz.
Control
switch
Black
PE
Wiring Diagrams
Case Dimensions and Methods of Installation
Page 2 of 2
Dowel
Adjustment
Screw
Tensioning
Cable
Draper’s Tab-Tensioning System is factory-set, and 
under normal circumstances will not require fi eld 
adjustment. If, however, you notice wrinkles, waves, or 
other indications that the tensioning cables need to be 
adjusted, follow the procedure below.
➀ Determine which side requires adjustment.
➁ Secure dowel with one hand.
Caution: Do not touch or bend surface.
➂ Using Philips-head screwdriver, depress 
  spring-loaded adjustment screw (see 
  Fig. 1) and slowly turn clockwise to tighten 
  tension, or counterclockwise to loosen tension.
  The screw adjusts in ¼ turn increments. Adjust 
 only 
one increment (¼ turn).
➃ If problem is not corrected, leave screen in position 
  for 24 hours to allow surface material to stretch into position.
➄ If problem still is not corrected, repeat steps 2 and 3.
Tab-Tensioning Cable Adjustment
Figure 1
www.draperinc.com
(765) 987-7999
MC1
See separate Serial Communication-RS232 Instruction sheet for 
enabling RS232 with the MC1.
3 Button Wall Switch 
DOWN - Black
COM - White
UP - Red
Eye Port for IR Eye, RF Receiver or LED
Switch For more than one of these, 
a splitter is required.
Aux Port for connecting additional
LVC-III modules (up to six total-
connect from Aux to Eye).
Red-to screen (directional)
Brown-to screen (directional)
White-Common to screen, 110-120V AC
Black-to 110-120V AC
Yellow-to 110-120V AC
Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Terminal strip in
junction box at left
end of screen
230V, 50 Hz.
Neutr
al
Hot
All-Pole Disconnect
by Others
STOP
Control 
Switches
24v DC
STOP
RS232 Data FROM Control System
RS232 Data TO Control System
Signal Ground & Manual Switch Common
Manual Switch Down
Manual Switch Up
Red-to Screen (directional)
Black-to Screen (directional)
Blue-Common
Brown-Hot to 230V AC
Green/Yellow-Ground
Fuse
Program LED
Eye Port for IR Eye. For RF Receiver 
or LED Wall Switch, a Splitter and a 
Power Supply is required. Plug RF 
Receiver or LED Wall Switch and 
Power Supply into splitter, then run 
cable from Splitter to MC1 Eye Port.
Low Voltage Wiring by others
AC Wiring by electrician
MC1
Terminal strip in
junction box at left
end of screen
230V, 50 Hz.
Neutr
al
Hot
All-Pole Disconnect
by Others
STOP
Control 
Switches
24v DC
STOP
Low Voltage & Wireless Control
SCREEN SIZE 
CASE SIZE
Total Drop < 396 cm or viewing width < 366 cm 
Small
Total Drop > 396 cm or viewing width > 366 cm 
Large
NOTE: Viewing surface shown is Series V with tab tensioning. 
Series E, without tab tensioning, is  also available.
Case length
38 mm Typ
Viewing surface
54 mm
A
 Series 
A
 E-small case  81 mm
 E-large case  114 mm
 V  Varies
Ceiling grid 
and tile
(by others)
232
cm
152
mm
248
cm
Audience
Electrical connection
to internal splice box
on left end of case. 22mm
knockout for 13 mm
conduit. J-Box cover located
under splice box.
Shown with
9.5 mm 
threaded rod
(provided
by others).
Ceiling grid and tile
(by others)
Audience
Electrical connection
to internal splice box
on left end of case. 22mm
knockout for 13 mm
conduit. J-Box cover located
under splice box.
Shown with
11 mm 
 threaded
rod (provided
by others).
Ceiling grid and tile
(by others)
232
cm
152
mm
280
cm
Small Signature Case
Large Signature Case