Toshiba B-SX4T ユーザーズマニュアル

ページ / 120
APPENDIX 2  INTERFACE 
ENGLISH VERSION EO1-33058 
APPENDIX 2  INTERFACE
 
EA2- 1 
APPENDIX 2  INTERFACE 
 
 
 
 
 
 
 
 
 
 
 
Parallel interface (Centronics) (Standard) 
Mode: 
Conforming to IEEE1284  
Compatible mode (SPP mode), Nibble mode, ECP mode 
Data input method:  8 bit parallel 
Control signal: 
 
 
 
 
 
 
 
 
 
 
 
Data input code: 
ASCII code 
European 8 bit code 
Graphic 8 bit code 
JIS8 code 
Shift JIS Kanji code 
JIS Kanji code 
 
Receive buffer: 
1M byte 
 
 
 
 
SPP Mode 
Nibble Mode ECP 
Mode 
nStrobe HostClk  HostClk 
nAck PtrClk  PeriphClk 
Busy PtrBusy PeriphAck 
Perror AckDataReq 
NAckReverse 
Select Xflag 
Xflag 
nAutoFd HostBusy  HostAck 
nInit nInit  nReverseRequest 
nFault nDataAvail 
nPeriphRequest 
nSelectIn IEEE1284Active 
IEEE1284Active 
NOTE: 
To prevent radiation and reception of electrical noise, the interface cables must meet the following requirements: 
•  In case of a parallel interface cable or serial interface cable, fully shielded and fitted with metal or metallised
connector housings. 
•  Keep as short as possible. 
•  Should not be bundled tightly with power cords. 
•  Should not be tied to power line conduits
•  A parallel interface cable to be used should conform to IEEE1284.