Controller specifications and requirements
Installation Planning Guide
5-3
WARNING
To reduce the risk of electrical shock, do not plug 
components into any other type of power system. Contract 
your facilities manager or a qualified electrician if you are 
not sure what type of power is supplied to your work area.
Environmental specifications
The environmental requirements for the DocuColor NPS/IPS 
controller are all satisfied by the printer module. Refer to the 
“Printer specifications and requirements” chapter of this guide.
The heat dissipation for the printer controller (processor and 
monitor) is 1,100 BTU per hour.
Space requirements
This section provides recommendations for placement of printer 
controller hardware components. 
For printer component space requirements, refer to the “Printer 
specifications and requirements” chapter of this guide. Contact 
your service representative if you have questions not specifically 
addressed in this guide.
Printer controller placement
You should consider the following factors when deciding where to 
place the DocuColor printer controller:
Adequate work space and service clearance around the 
equipment
Proximity to electrical and network connectors
Security of the work area. You may need to place the system 
in an area where you can restrict access to it. 
You must supply a table or desk as a work surface for the printer 
controller, and the PCI board if this is part of the system 
configuration. The top of the table must provide at least 36 by 36 
inches / 91 by 91 cm of space for each component, to allow 
enough space for the components and cables, as well as for 
service access.