Epson S1D13504 ユーザーズマニュアル

ページ / 504
Epson Research and Development
Page 3
Vancouver Design Center
13504SPLT Display Utility
S1D13504
Issue Date: 01/01/30 
X19A-B-003-05
 13504SPLT
13504SPLT demonstrates S1D13504 split screen capability by showing two different areas of 
display memory on the screen simultaneously. Screen 1 shows horizontal bars, and Screen 2 
shows vertical bars.
Screen 1 memory is located at the start of the display buffer. Screen 2 memory is located immedi-
ately after Screen 1 in the display buffer. On user input or elapsed time, the line compare register 
value is changed to adjust the amount of area displayed on either screen. 
The 13504SPLT display utility must be configured and/or compiled to work with your hardware 
platform. Consult documentation for the program 13504CFG.EXE which can be used to configure 
13504SPLT.
This software is designed to work in both embedded and personal computer (PC) environments. For 
the embedded environment, it is assumed that the system has a means of downloading software from 
the PC to the target platform. Typically this is done by serial communications, where the PC uses a 
terminal program to send control commands and information to the target processor. Alternatively, 
the PC can program an EPROM, which is then placed in the target platform. Some target platforms 
can also communicate with the PC via a parallel port connection, or an Ethernet connection.
S1D13504 Supported Evaluation Platforms
13504SPLT has been tested with the following S1D13504 supported evaluation platforms:
• PC system with an Intel 80x86 processor.
• M68332BCC (Business Card Computer) board, revision B, with a Motorola MC68332 
processor.
• M68EC000IDP (Integrated Development Platform) board, revision 3.0, with a Motorola 
M68EC000 processor.
• SH3-LCEVB board, revision B, with an Hitachi SH-3 HD6417780 processor.
If the platform you are using is different from the above, please see the S1D13504 “Programming 
Notes and Examples” manual, document number X19A-G-002-xx.
Installation
PC platform: copy the file 13504SPLT.EXE to a directory that is in the DOS path on your hard 
drive.
Embedded platform: download the program 13504SPLT to the system.