Epson S1D13504 ユーザーズマニュアル

ページ / 504
Epson Research and Development
Page 11
Vancouver Design Center
13504DCFG Configuration Program
S1D13504
Issue Date: 01/02/01 
X19A-B-008-02
Clocks Tab
Figure 3: Clocks Tab
The Clocks Tab allows manual selection of either the clocks or the required timings. From 
this information 13504DCFG calculates the required timings (if clocks are specified) or the 
required clocks (if timings are specified). The program calculates the clocks automatically 
when the “Auto” setting is checked. 
If clock selections are manually changed, it may modify or invalidate CRT or panel timings 
selected previously. Changing the settings on the Clocks Tab alters the settings on the Panel 
and CRT Tabs. Confirm all settings on these two tabs after manually changing any clock 
settings.
Note
If the same source clock is selected for use by both CRT and LCD panels, the available
LCD pixel clock selections are limited due to the more stringent CRT timings.