Printronix L5035 ユーザーズマニュアル

ページ / 278
Chapter 3
Printer Configuration
86
 
Data Polarity
Values: Standard (default) or Inverted.
This parameter must be set to match the Data signal polarity of 
your host computer.
There are normally seven or eight data bits that define each ASCII 
character sent from the host computer to the printer. The bits are 
usually high-true.
Strobe Polarity
Values: Standard (default) or Inverted.
This parameter must be set to match the Data Strobe signal polarity 
of your host computer.
When the host computer sends a data strobe signal, it is indicating 
that it has placed data on the data bus and that the data is valid 
(i.e., enough time has elapsed for the data lines to stabilize). The 
data strobe signal forces the printer to read the data lines into its 
input buffer.
Data Req (Request) Polarity
Values: Standard (default) or Inverted.
This parameter must be set to match the Data Request signal 
polarity of your host computer.
Data Request is a high-true signal sent by the printer requesting 
data from the host.
Ready Polarity
Values: Standard (default) or Inverted.
This parameter must be set to match the Ready signal polarity of 
your host computer.
When the printer is ready to receive data, it sends a Ready signal to 
the host.