Calibration
36 
11. Power the printer off, wait a few seconds, then power the 
printer on.
If the calibration was successful, the scanning beam is on and 
the CALIBRATION light is off.
If the calibration was not successful, the scanning beam 
remains on and the CALIBRATION light stays lit without 
flashing. Repeat the calibration procedure. If repeated attempts 
fail, check the room for excessive ambient light, including direct 
sunlight. You may need to move the printer to a darker area of 
the room.
NOTE: In some cases the validator can detect and indicate to the 
printer that calibration is required. See “Calibration 
warning” in Table 6, page 86.
Bar Code Validation Demo Page
The bar code validation demo page allows you to test or 
demonstrate the validator operation without a host computer. This 
page contains some text and two good bar code symbologies: one 
in Code 39, the other in Code 128.
To print and validate the bar code validation demo page:
1.
Load the factory default configuration. (Refer to the 
User’s 
Manual.)
2.
In the VALIDATOR menu, set Validator Funct. to Enable.
3.
In the CALIBRATE CTRL menu, set Gap/Mark Sensing to Gap.
4.
Load media.
5.
In the CALIBRATE CTRL menu, run Auto Calibrate for proper 
gap sensing.
6.
The printer must be offline. If the printer is in Menu mode, press 
the PAUSE key to take the printer offline.
7.
Press the TEST PRINT key to enter the Test Print menu. 
Continue to press TEST PRINT until Barcode Demo displays.
8.
Press the 
 key to print and validate the demo page. (If the 
 
key is locked, unlock it by pressing 
 and 
 at the same time.)