Printronix T5000R ユーザーズマニュアル

ページ / 102
Advanced Validator Options
65
The following is a sample scan report of a Code 39, 10 mil bar code 
containing "*RJS8702*" with a quiet zone violation:
SCAN REPORT
ERROR: Bar code quiet zone too small
Barcode Data: [ST]RJS8702[ST]
Symbology
Code 39
Overall Grade
C (2.1)
X dimension (mils)
09.9
Decodeability (%)
65
Modulation (%)
34
Symbol Contrast (%)
68
Edge Contrast (%)
30
Defects (%)
14
Rmin/Rmax
2
PCS
92
Percent Decode (%)
100
Bar Deviation Avg (%)
-16
Min. Bar Deviation (%)
-31
Max. Bar Deviation (%)
-4
Ratio
2.0
Good Scans
28
Total Scans
30
Scan Profile
This is an executable menu that prints the scan reflectance profile 
of a bar code placed in the validator scan beam.
NOTE: You will need a minimum installed label width of 2 inches
to support the Scan Profile printout.
1.
Press 
 to take the printer offline and place the printer in 
Menu mode.
2.
If necessary, press 
↓ 
and 
 at the same time to unlock the 
key.
3.
If necessary, press 
 until VALIDATOR displays.
4.
Press 
↑ 
until Scan Profile displays.
5.
Place a bar code in the scan beam path.
6.
Press 
 to scan the bar code.
7.
When prompted on the control panel, remove the scanned bar 
code.
8.
Press 
 to print the scan profile.
..
.
..
.