Sharp FODC550 ユーザーズマニュアル

ページ / 116
TROUBLESHOOTING AND MAINTENANCE
81
8
2
Gently remove the misfed paper 
from under the fusing unit as shown 
in the illustration. If the paper cannot 
be removed, proceed to "C: Misfeed 
in the transport area".
3
Raise the fusing unit release lever and then close the side 
cover by pressing the round projections near the side cover 
open button. The error indicator will go out and the ready 
indicator will light up.
C: Misfeed in the transport area
1
Lower the fusing unit release lever.
2
Open the front cover.
To open the front cover, see "TD CARTRIDGE REPLACEMENT" (p.84).
3
Rotate the roller rotating 
knob in the direction of the 
arrow and gently remove the 
misfed paper from the exit 
area.
The fusing unit is hot. Do not touch the fusing unit when 
removing misfed paper. Doing so may cause a burn or other 
injury.
• Do not touch the surface (green portion) of the drum cartridge when 
removing the misfed paper. Doing so may cause damage the drum 
cartridge and smudges on copies.
• Do not remove the misfed paper from above the fusing unit. Unfixed 
toner on the paper may stain the paper transport area, resulting in 
smudges on copies.
Warning
Caution
Roller rotating 
knob