Define the Timing Trigger Term "Edge 1"
The timing analyzer can be configured to trigger on edges, or a glitch. In this
exercise, you will set the trigger term to glitch on bit 7.
exercise, you will set the trigger term to glitch on bit 7.
1
1
Press the
Trigger
MENU key.
2
Highlight the
Modify Trigger
field, and press the
Select
key. Highlight
Clear Trigger
, press the
Select
key, then highlight
All
, and press the
Select
key.
3
Highlight the base field below
TCOUNT
, and press the
Select
key.
Highlight
Binary
in the pop-up menu, and press the
Select
key.
4
Highlight the field to the right of
Edge 1
, and press the
Select
key.
5
Using the arrow key, move the cursor to highlight the asterisk in the
pop-up menu for bit 7. Press the
pop-up menu for bit 7. Press the
Done
key.
The asterisk tells the analyzer to look for a glitch on bit 7 of the counter.
Defining Timing Trigger Terms Edge 1
Result
The term "Edge 1" is defined as a glitch on bit 7.
Edge 1
Bit 7
Triggering the Oscilloscope with the Timing Analyzer
Define the Timing Trigger Term "Edge 1"
Define the Timing Trigger Term "Edge 1"
8-10