Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
7 - 6 
MELSEC-Q
 
7   MEMORY CONFIGURATION AND DATA PROCESS 
  
Buffer memory address 
Buffer memory area configuration 
Axis 1 
Axis 2 
Axis 3 
Axis 4 
Writing 
possibility 
Basic setting parameter area 
30100 to 
30115 
30300 to 
30315 
30500 to 
30515 
30700 to 
30715 
Gain 
• filter setting parameter 
area 
30119 to 
30152 
30319 to 
30352 
30519 to 
30552 
30719 to 
30752 
Expansion setting parameter 
area 
30164 to 
30184 
30364 to 
30384 
30564 to 
30584 
30764 to 
30784 
Servo parameter area 
Input/output setting parameter 
area 
30202 to 
30204 
30402 to 
30404 
30602 to 
30604 
30802 to 
30804 
Possible 
 
            Use of address Nos. skipped above is prohibited. If used, the system may not operate correctly. 
 
 
POINT 
 
When the parameter of the servo amplifier side is changed, it is transmitted to the servo memory area 
in the buffer memory after the QD75MH is read automatically with parameters. 
(1) When changing the servo parameters by the auto tuning. 
(2) When the servo parameter is changing after the MR-configurator is connected directly with the servo 
amplifier.