Mitsubishi Electronics QD75MH2 ユーザーズマニュアル

ページ / 838
 
 
 
9 - 13 
MELSEC-Q
 
9   MAJOR POSITIONING CONTROL 
 
[When the speed cannot change over in P2] 
When the relation of the speeds is P1 = 
P4, P2 = P3, P1 < P2. 
 
[When the movement amount is small during 
automatic deceleration] 
The movement amount required to carry out the 
automatic deceleration cannot be secured, so the 
machine immediately stops in a speed ≠ 0 status. 
P1
P2
P3
P4
Positioning address.
 
 
(b)  Front-loading speed switching mode 
 
1)  If the respective command speeds differ in the "positioning data 
currently being executed" and the "positioning data to carry out 
the next operation", the speed will change over to the speed set in 
the "positioning data to carry out the next operation" at the end of 
the "positioning data currently being executed".  
 
2)  The parameters used in acceleration/deceleration to the 
command speed set in the "positioning data to carry out the next 
operation" are those of the positioning data to carry out 
acceleration/deceleration. 
Speed switching will not be carried out if the command speeds 
are the same.  
 
OFF
ON
OFF
ON
OFF
ON
OFF
ON
11
11
11
01
00
V
Dwell time
t
Da. 1 Operation pattern 
Start complete signal
BUSY signal
Positioning complete signal
Positioning start signal
Positioning
[Y10, Y11, Y12, Y13]
[X10, X11, X12, X13]
Dwell time
[XC, XD, XE, XF]
[X14, X15, X16, X17]
 